The centrifugal filter is a disposable filtration device that combines centrifugal force and ultrafiltration technology to provide reliable data for concentration, desalination and buffer exchange of protein samples in biological experiments. Compared with chromatography and dialysis, the ultrafiltration centrifuge tube handles molecules more gently, does not require organic extraction, does not lead to protein denaturation, operates quickly and simply and efficiently, and separates molecules while the concentration multiplier is It is fast, simple and efficient.
Inner Filter Specification: 0.5mL 5mL 15mL
Molecular weight cut off (MWCO): 5KD 10KD 30KD 50KD 100KD
* Outer tube: Polypropylene (PP)
* Filter:Methacrylate-Butadiene-Styrene (MBS)
* Filter membrane: Polyethersulfone (PES)
* Tube cap: High-density polyethylene (HDPE)
* Conforming to USP Class VI standards
* All materials are confirming to USP Class VI . In total, five molecular weight cut-off (MWCO) options are available, meeting the needs of filtering molecules in different sizes.
* The filter is structurally designed with a high-performance vertical single- (0.5 mL)/double-sided (5 mL & 15 mL) PES filtration membrane, featuring a larger effective filtration area and a higher flow rate.
* The 5 mL and 15 mL tubes are provided with supports, improving the stability of the structure, supporting a higher centrifugal speed, and reducing the filtration time.
* The protein recovery is increased to over 80%.
* There is a printed scale and a white area for writing on the tube, facilitating the identification and marking.
* 100% undergone for production line air tightness test
* DNase-free, RNase-free, non-pyrogenic
Product applications:
* Desalting, diafiltration or changing of buffers
* Concentration and purification of biological samples, including antigens, antibodies, enzymes, nucleic acids (single or double strain DNA/RNA samples), microorganisms, and eluates.
* Purification of macromolecular components from tissue culture extracts or cell lysates
* Removal of primers, ligation or molecular markers from the reaction mixture, removal of proteins prior to HPLC.
Warning:
* The product is inapplicable to solutions containing benzene, acetone, and chloroform.
Cat. No. | Inner Filter Specification (mL) |
Tube Specification (mL) |
Effective Filtration Area (cm2) | Maximum Initial Sample Volume | Sterilization | MWCO (KDa) | Maximum Centrifugal Force (Fixed Angle Rotor) × g | Maximum Centrifugal Force (Swinging Bucket Rotor) × g | Qty. per Box/Case |
FTT105105 | 0.5 | 2 | 0.65 | 0.5 mL for fixed angle rotor | N | 5 | 10000 | - | 25/300 |
FTT110105 | 0.5 | 2 | 0.65 | N | 10 | 10000 | - | 25/300 | |
FTT130105 | 0.5 | 2 | 0.65 | N | 30 | 10000 | - | 25/300 | |
FTT150105 | 0.5 | 2 | 0.65 | N | 50 | 10000 | - | 25/300 | |
FTT100105 | 0.5 | 2 | 0.65 | N | 100 | 10000 | - | 25/300 | |
FTT105150 | 5 | 15 | 3.5 |
4 mL for fixed angle rotor, 5 mL for swinging bucket rotor |
N | 5 | 5000 | 4000 | 24/96 |
FTT110150 | 5 | 15 | 3.5 | N | 10 | 5000 | 4000 | 24/96 | |
FTT130150 | 5 | 15 | 3.5 | N | 30 | 5000 | 4000 | 24/96 | |
FTT150150 | 5 | 15 | 3.5 | N | 50 | 5000 | 4000 | 24/96 | |
FTT100150 | 5 | 15 | 3.5 | N | 100 | 5000 | 4000 | 24/96 | |
FTT405500 | 15 | 50 | 9.7 | 12 mL for fixed angle rotor, 15 mL for swinging bucket rotor | N | 5 | 4000 | 3000 | 8/96 |
FTT505500 | 15 | 50 | 9.7 | N | 5 | 4000 | 3000 | 24/96 | |
FTT410500 | 15 | 50 | 9.7 | N | 10 | 4000 | 3000 | 8/96 | |
FTT510500 | 15 | 50 | 9.7 | N | 10 | 4000 | 3000 | 24/96 | |
FTT430500 | 15 | 50 | 9.7 | N | 30 | 4000 | 3000 | 8/96 | |
FTT530500 | 15 | 50 | 9.7 | N | 30 | 4000 | 3000 | 24/96 | |
FTT450500 | 15 | 50 | 9.7 | N | 50 | 4000 | 3000 | 8/96 | |
FTT550500 | 15 | 50 | 9.7 | N | 50 | 4000 | 3000 | 24/96 | |
FTT400500 | 15 | 50 | 9.7 | N | 100 | 4000 | 3000 | 8/96 | |
FTT500500 | 15 | 50 | 9.7 | N | 100 | 4000 | 3000 | 24/96 |