Home
Product Biological Laboratory Consumables Cell Culture CellATTACH® Cell and Tissue Culture Products
内页720×540 拷贝.jpg
内页720×540 拷贝2.jpg
内页720×540 拷贝1.jpg

CellATTACH® Cell and Tissue Culture Products

Cell and Tissue Culture Flasks:T12.5  T25  T75  T182  T300
Cap Style:Plug Seal  Vent
Cell and Tissue Culture Plates: 6-well  12-well  24-well  48-well  96-well
Cell and Tissue Culture Dishes :35 mm   60 mm   70 mm   90 mm   100 mm   150 mm

Get Quotation
Introduction
Product Information
Order Information
FAQ
Recommended Products

Introduction

Product Information

The CellATTACH® superhydrophilic cell culture product series is created by introducing polar groups onto their surfaces. This forms a durable and stable superhydrophilic surface that facilitates good adherent growth of various types of cells under different culture conditions, thereby improving cell yield. The treated surface also eliminates the need for unstable, time-consuming, and costly biological coating.

Features

* Unique super-hydrophilic surface treatment technology provides better adherence for cells, promoting rapidly cell growth and increasing yields
* This ensures continuous and uniform cell adherence, and can be used for adherent cultures of primary cells, neuronal cells, stem cells and other hard-to-nourish cells that have higher or more stringent requirements for the hydrophilicity of the culture surface
* Cells can adapt quickly to a serum-free or low-serum culture environment, meeting the needs of experiments that have to eliminate the interference of serum components or that require reduced serum levels, thus saving cost of cell culture




Material

* Flask/Plate/Dish Body: Polystyrene (PS)
* Flask Cap: High-density Polyethylene (HDPE)
* Filter Membrane: Polytetrafluoroethylene (PTFE)
* Conforming to USP Class VI standards

Product Information

Jet Biofil ENG Catalogue 2025

Catalogue

Jet Biofil ENG Catalogue 2025

Download File

Order Information

CellATTACH® Cell and Tissue Culture Flasks
Cat. No. Volume(mL) Culture Surface Area(cm²) Maximum Working Volume(mL) Recommended Working Volume(mL) Type of Cap Length (mm) Width (mm) Height (mm) Sterile Qty. Per Bag Qty. Per Case
CAF011025 25 12.5 8.0 2.5 - 3.8 Plug Seal 73.7 40.4 22.8 Y 10 200
CAF012025 25 12.5 8.0 2.5 - 3.8 Vent 73.7 40.4 22.8 Y 10 200
CAF011050 50 25.0 17.5 5.0 - 7.5 Plug Seal 92.9 49.5 29.1 Y 10 200
CAF012050 50 25.0 17.5 5.0- 7.5 Vent 92.9 49.5 29.1 Y 10 200
CAF011250 250 75.0 60.0 15.0 - 22.5 Plug Seal 152.5 81.5 35.2 Y 5 100
CAF012250 250 75.0 60.0 15.0 - 22.5 Vent 152.5 81.5 35.2 Y 5 100
CAF011600 600 182.0 125.0 36.4 - 54.6 Plug Seal 219.3 115.7 38.3 Y 5 40
CAF012600 600 182.0 125.0 36.4 - 54.6 Vent 219.3 115.7 38.3 Y 5 40
CAF111600 600 182.0 (Extended) 200.0 36.4 - 54.6 Plug Seal 219.3 115.7 49.5 Y 5 40
CAF112600 600 182.0(Extended) 200.0 36.4 - 54.6 Vent 219.3 115.7 49.5 Y 5 40
CAF011850 850 300.0 200.0 60.0 - 90.0 Plug Seal 269.2 116.0 47.0 Y 3 18
CAF012850 850 300.0 200.0 60.0 - 90.0 Vent 269.2 116.0 27.0 Y 3 18


CellATTACH®Cell and Tissue Culture Dishes

Cat. No. Diameter (mm) Height (mm) Recommended Working Volume(mL) Culture Area (cm²) Qty. per Bag Qty. per Case
CAD010035 35 12.6 2-3.5 8.5 10 240
CAD010060 60 17.3 4-7 21.2 10 240
CAD010070 70 15.5 6-11 36.3 10 240
CAD010090 90 16.9 10-18 55.0 10 240
CAD010100 100 22.6 12-20 60.8 10 240
CAD010150 150 22.7 25-50 143.0 5 80


CellATTACH®Cell and Tissue Culture Plates
Cat. No. Well Qty. Bottom Type Well Maximum
Working Volume (mL)
Well Recommended
Working
Volume (mL)
Qty. Per
Pack
Qty. Per
Case
CAP011006 6 Flat 17.0 1.90~2.90 1 100
CAP011012 12 Flat 6.8 0.76~1.14 1 100
CAP011024 24 Flat 3.5 0.38~0.57 1 100
CAP011048 48 Flat 1.6 0.19~0.29 1 100
CAP011096 96 Flat 0.3 0.08~0.20 1 100
CAP012096 96 U-shape 0.3 0.08~0.20 1 100

FAQ

FAQ about cell culture plates/bottles/dishes

* What does TC-treated in the product name mean?

TC-treated means that Tissue Cultured is used to treat the surface. By means of corona discharge or gas plasma, Jet Biofil can improve the hydrophilicity of polystyrene (PS) surface, improve the adhesion of proteins needed for cell adhesion, and thus help cells adhere to the wall.

 

* Which surface should I use to culture suspension cells?

The suspension cells do not have the need for cell adhesion, and generally the culture supplies for untreated surface can be used. TC-treated surface can also culture suspension cells, but according to the state and type of cells, some cells may appear adhesion phenomenon.

 

* If I want to coat extracellular matrix myself, what kind of surface should I use?

You can choose the culture vessel with untreated surface to coat the extracellular matrix by yourself. Of course, in this case, vessels with TC-treated surface can also be used

 

* How to use the cell culture bottle with a sealed cap? What are the differences between the use of cell culture bottles with filter membrane caps?

Cell culture bottles with sealed caps provide a closed cell culture environment. If it is needs to connect with the air in the incubator, it is necessary to slightly loosen the cap after the bottle is put into the incubator to allow air to enter. Similarly, when taking out the bottle, tighten the cap first and then take it out. The cap with the filter membrane itself has the function of breathable, and the filter membrane can prevent microbial contamination. Therefore, the cap of the culture bottle can be directly tightened and put into the incubator during use, but it needs to be noted that the filter membrane on the cap cannot be wet, wet filter membrane cannot ensure the passage of gas.

 

* What does T25, T175 mean that I often hear?

Taking T25 as an example, it refers to a cell culture bottle with a growth surface area of 25 cm2. According to the type of bottle cap and different culture surfaces, different article numbers correspond to different products.

 

* I bought the product with article number xxxxxx. What is its growth area? How much medium should I add to culture my cells?

We recommend using 0.2-0.3mL/cm2 of medium

 

* The cell culture bottle/dish I bought is not vacuum packed. The bag looks loose. Is there a quality problem?

The cell culture supplies of Jet Biofil are not vacuum packed, and are only manually aspirated for convenient transportation, so there will be differences. In addition, the temperature and air pressure in different regions will also affect the tightness of the packaging. If there is no air leakage in the package and the cap does not fall off from the product, it will not affect the sterility of the product and the quality of the product. Please feel relieved the use. If the package is damaged or the air leaks or the cover falls off from the product, please take a photo and submit a complaint through your dealer. At the same time, please pay attention to provide a photo of the outer box of the product. When you receive the goods, please carefully confirm whether the outer box is damaged or deformed.

 

* I can’t use up a package of culture supplies in one experiment. How should I preserve it?

We cannot guarantee the sterility of the product after opening. We suggest that you store it in a sterile environment, control the temperature and humidity of the environment, and avoid the storage under light/ultraviolet irradiation.

 

* I used the culture bottle/dish/plate of Jet Biofil, and the cells did not adhere to the wall. Is it a product quality problem?

There are many factors that lead to non-adherent cells, such as culture medium composition and pH value, culture environment, digestion operation, cell type, cell passage, etc. If you use the same product with the same article number to culture the same cell strain for a long time, and the cells adhere normally before, but do not adhere to the wall now, it is recommended that you timely record the batch number of the products used in both cases, and conduct repeated parallel experiments, that is, use cells from the same source to spread on the supplies of these two batches for culture (pay attention to using the culture medium from the same source). Culture in the same incubator to determine the main reason why cells do not adhere to the wall.

 

* The color of the culture bottle/dish/plate I bought this time is more yellow than that of last time. Is it a product quality problem?

It is normal that plastic consumables of different batches may turn yellow after irradiation sterilization.


FAQ

Recommended Products

Return to Previous Page