Home
Product Biological Laboratory Consumables Cell Culture Cell and Tissue Culture Flasks
内页720×540 拷贝1 英文.jpg
内页720×540 拷贝3.jpg
内页720×540 拷贝5.jpg
细胞培养瓶2.jpg
内页720×540 拷贝2.jpg
内页720×540 拷贝4.jpg

Cell and Tissue Culture Flasks

Specification: T12.5 T25 T75 T150 T175 T182 T182 (Extra Height) T225 T300
Type of Cap: Plug Seal   Vent
Surface: Non-treated    TC-treated    CellATTACH®-treated

Get Quotation
Introduction
Product Information
Order Information
FAQ
Recommended Products

Introduction

Product Information

Cell and tissue culture flasks are the most suitable culture vessels for long-term and large-scale laboratory cell culture while preventing contamination. The surface untreated flasks are suitable for suspension cells culture, while those with a TC-treated surface are suitable for common adherent cell lines due to the excellent hydrophilicity of the polystyrene surface. The CellATTACH® superhydrophilic treated surface represents a technical advancement that improves the adhesion and growth of difficult-to-nourish cells, primary cells and transfection cell lines under low serum/serum-free conditions.

0.22 µm PTFE hydrophobic vent cap  supports gas exchange and prevents  cross-contamination.

0.22 µm PTFE hydrophobic vent cap supports gas exchange and prevents cross-contamination.

Ergonomic cap design - open/close by  otating 1/4 of its full range.

Ergonomic cap design - open/close by otating 1/4 of its full range.

The tilted bottleneck facilitates liquid  pouring, as well as convenient operations  of pipettes and cell scrapers.

The tilted bottleneck facilitates liquid pouring, as well as convenient operations of pipettes and cell scrapers.

Clear graduations are shown on both sides  and the frosted area can be marked.

Clear graduations are shown on both sides and the frosted area can be marked.

Features

* Various treated surfaces are suitable for different culture needs
* The hydrophobic vent cap ensures continuous ventilation, enabled by turning the cap 1/4 of its full range
* The tilted bottleneck facilitates easy access of pipets and cell scrapers
* Low profile design supports effective use of the internal space of the incubator when stacked
* The frosted area near the bottleneck can be written on
* Volume graduations molded on both sides
* 100% tested for production line leakage
* Lot No. on the bottom of each flask and package bag for quality traceability
* Sterilized by irradiation, SAL 10-6
* DNase/RNase free, non-pyrogenic and non-cytotoxic

Material

* Flask Body: Polystyrene (PS)
* Bottle Cap: High-density Polyethylene (HDPE)
* Filter Membrane: Polytetrafluoroethylene (PTFE)
* Conforming to USP Class VI standards

Product Information

T225 Cell and Tissue Culture Flask

Brochure

T225 Cell and Tissue Culture Flask

Download File
T150 U-Shaped Cell and Tissue Culture Flask

Brochure

T150 U-Shaped Cell and Tissue Culture Flask

Download File
T150 U-Shaped Cell and Tissue Culture Flask
Jet Biofil ENG Catalogue 2025

Catalogue

Jet Biofil ENG Catalogue 2025

Download File

Order Information


Cell and Tissue Culture Flasks , Non-treated
Cat. No. Volume(mL) Culture Surface Area(cm²) Type of Cap Maximum Working Volume(mL) Length(mm) Width(mm) Height(mm) Botte Neck Diameter(mm) Sterile Qty. Per Bag Qty. Per Case
TCF001025 25 12.5 Plug Seal 8.0 73.7 40.4 22.8 14.2 Y 10 200
TCF002025 25 12.5 Vent 8.0 73.7 40.4 22.8 14.2 Y 10 200
TCF001050 50 25.0 Plug Seal 17.5 92.9 49.5 29.1 18.2 Y 10 200
TCF002050 50 25.0 Vent 17.5 92.9 49.5 29.1 18.2 Y 10 200
TCF001250 250 75.0 Plug Seal 60.0 152.5 81.5 35.2 25.0 Y 5 100
TCF002250 250 75.0 Vent 60.0 152.5 81.5 35.2 25.0 Y 5 100
TCF001150 375 150.0 (U-shaped) Plug Seal 140.0 199.7 111.3 111.3 25.6 Y 5 8
TCF002150 375 150.0 (U-shaped) Vent 140.0 199.7 111.3 111.3 25.6 Y 5 50
TCF001175 600 175.0 Plug Seal 250.0 199.9 122.7 49.2 25.7 Y 5 50
TCF002175 600 175.0 Vent 250.0 199.9 122.7 49.2 25.7 Y 5 50
TCF001600 600 182.0 Plug Seal 125.0 219.3 115.7 38.3 29.5 Y 5 40
TCF002600 600 182.0 Vent 125.0 219.3 115.7 38.3 29.5 Y 5 40
TCF101600 600 182.0 (Extended) Plug Seal 200.0 219.3 115.7 49.5 29.5 Y 5 40
TCF102600 600 182.0 (Extended) Vent 200.0 219.3 115.7 49.5 29.5 Y 5 40
TCF001225 850 225.0 Plug Seal 400.0 221.9 137.2 49.5 25.7 Y 5 25
TCF002225 850 225.0 Vent 400.0 221.9 137.2 49.5 25.7 Y 5 25
TCF001850 850 300.0 Plug Seal 200.0 269.2 166.0 47.0 29.5 Y 3 18
TCF002850 850 300.0 Vent 200.0 269.2 166.0 47.0 29.5 Y 3 18


Cell and Tissue Culture Flasks, TC-treated
Cat. No. Volume(mL) Culture Surface Area(cm²) Type of Cap Recommended Working Volume(mL) Maximum Working Volume(mL) Length(mm) Width(mm) Height(mm) Botte Neck Diameter(mm) Sterile Qty. Per Bag Qty. Per Case
TCF011025 25 12.5 Plug Seal 2.5-3.8 8.0 73.7 40.4 22.8 14.2 Y 10 200
TCF012025 25 12.5 Vent 2.5-3.8 8.0 73.7 40.4 22.8 14.2 Y 10 200
TCF011050 50 25.0 Plug Seal 5.0-7.5 17.5 92.9 49.5 29.1 18.2 Y 10 200
TCF012050 50 25.0 Vent 5.0-7.5 17.5 92.9 49.5 29.1 18.2 Y 10 200
TCF011250 250 75.0 Plug Seal 15.0-22.5 60.0 152.5 81.5 35.2 25.0 Y 5 100
TCF012250 250 75.0 Vent 15.0-22.5 60.0 152.5 81.5 35.2 25.0 Y 5 100
TCF011150 375 150.0 (U-shaped) Plug Seal 30.0-45.0 140.0 199.7 111.3 111.3 25.6 Y 5 50
TCF022150 375 150.0 (U-shaped) Vent 30.0-45.0 140.0 199.7 111.3 111.3 25.6 Y 5 50
TCF011175 600 175.0 Plug Seal 35.0-52.5 250.0 199.9 122.7 49.2 25.7 Y 5 50
TCF012175 600 175.0 Vent 35.0-52.5 250.0 199.9 122.7 49.2 25.7 Y 5 50
TCF011600 600 182.0 Plug Seal 36.4-54.6 125.0 219.3 115.7 38.3 29.5 Y 5 40
TCF012600 600 182.0 Vent 36.4-54.6 125.0 219.3 115.7 38.3 29.5 Y 5 40
TCF111600 600 182.0 (Extended) Plug Seal 36.4-54.6 200.0 219.3 115.7 49.5 29.5 Y 5 40
TCF112600 600 182.0 (Extended) Vent 36.4-54.6 200.0 219.3 115.7 49.5 29.5 Y 5 40
TCF011225 850 225.0 Plug Seal 60.0-90.0 400.0 221.9 137.2 49.5 25.7 Y 5 25
TCF012225 850 225.0 Vent 60.0-90.0 400.0 221.9 137.2 49.5 25.7 Y 5 25
TCF011850 850 300.0 Plug Seal 60.0-90.0 200.0 269.2 166.0 47.0 29.5 Y 3 18
TCF012850 850 300.0 Vent 60.0-90.0 200.0 269.2 166.0 47.0 29.5 Y 3 18

CellATTACH® Cell and Tissue Culture Flasks
Cat. No. Volume(mL) Culture Surface Area(cm²) Type of Surface Maximum Working Volume(mL) Recommended Working Volume(mL) Type of Cap Sterile Qty. Per Bag Qty. Per Case
CAF011025 25 12.5 CellATTACH® Treated 8.0 2.5 - 3.8 Plug Seal Y 10 200
CAF012025 25 12.5 8.0 2.5 - 3.8 Vent Y 10 200
CAF011050 50 25.0 17.5 5.0 - 7.5 Plug Seal Y 10 200
CAF012050 50 25.0 17.5 5.0- 7.5 Vent Y 10 200
CAF011250 250 75.0 60.0 15.0 - 22.5 Plug Seal Y 5 100
CAF012250 250 75.0 60.0 15.0 - 22.5 Vent Y 5 100
CAF011600 600 182.0 125.0 36.4 - 54.6 Plug Seal Y 5 40
CAF012600 600 182.0 125.0 36.4 - 54.6 Vent Y 5 40
CAF111600 600 182.0(Extended) 200.0 36.4 - 54.6 Plug Seal Y 5 40
CAF112600 600 182.0(Extended) 200.0 36.4 - 54.6 Vent Y 5 40
CAF011850 850 300.0 200.0 60.0 - 90.0 Plug Seal Y 3 18
CAF012850 850 300.0 200.0 60.0 - 90.0 Vent Y 3 18

FAQ

FAQ about cell culture plates/bottles/dishes

* What does TC-treated in the product name mean?

TC-treated means that Tissue Cultured is used to treat the surface. By means of corona discharge or gas plasma, Jet Biofil can improve the hydrophilicity of polystyrene (PS) surface, improve the adhesion of proteins needed for cell adhesion, and thus help cells adhere to the wall.

 

* Which surface should I use to culture suspension cells?

The suspension cells do not have the need for cell adhesion, and generally the culture supplies for untreated surface can be used. TC-treated surface can also culture suspension cells, but according to the state and type of cells, some cells may appear adhesion phenomenon.

 

* If I want to coat extracellular matrix myself, what kind of surface should I use?

You can choose the culture vessel with untreated surface to coat the extracellular matrix by yourself. Of course, in this case, vessels with TC-treated surface can also be used

 

* How to use the cell culture bottle with a sealed cap? What are the differences between the use of cell culture bottles with filter membrane caps?

Cell culture bottles with sealed caps provide a closed cell culture environment. If it is needs to connect with the air in the incubator, it is necessary to slightly loosen the cap after the bottle is put into the incubator to allow air to enter. Similarly, when taking out the bottle, tighten the cap first and then take it out. The cap with the filter membrane itself has the function of breathable, and the filter membrane can prevent microbial contamination. Therefore, the cap of the culture bottle can be directly tightened and put into the incubator during use, but it needs to be noted that the filter membrane on the cap cannot be wet, wet filter membrane cannot ensure the passage of gas.

 

* What does T25, T175 mean that I often hear?

Taking T25 as an example, it refers to a cell culture bottle with a growth surface area of 25 cm2. According to the type of bottle cap and different culture surfaces, different article numbers correspond to different products.

 

* I bought the product with article number xxxxxx. What is its growth area? How much medium should I add to culture my cells?

We recommend using 0.2-0.3mL/cm2 of medium

 

* The cell culture bottle/dish I bought is not vacuum packed. The bag looks loose. Is there a quality problem?

The cell culture supplies of Jet Biofil are not vacuum packed, and are only manually aspirated for convenient transportation, so there will be differences. In addition, the temperature and air pressure in different regions will also affect the tightness of the packaging. If there is no air leakage in the package and the cap does not fall off from the product, it will not affect the sterility of the product and the quality of the product. Please feel relieved the use. If the package is damaged or the air leaks or the cover falls off from the product, please take a photo and submit a complaint through your dealer. At the same time, please pay attention to provide a photo of the outer box of the product. When you receive the goods, please carefully confirm whether the outer box is damaged or deformed.

 

* I can’t use up a package of culture supplies in one experiment. How should I preserve it?

We cannot guarantee the sterility of the product after opening. We suggest that you store it in a sterile environment, control the temperature and humidity of the environment, and avoid the storage under light/ultraviolet irradiation.

 

* I used the culture bottle/dish/plate of Jet Biofil, and the cells did not adhere to the wall. Is it a product quality problem?

There are many factors that lead to non-adherent cells, such as culture medium composition and pH value, culture environment, digestion operation, cell type, cell passage, etc. If you use the same product with the same article number to culture the same cell strain for a long time, and the cells adhere normally before, but do not adhere to the wall now, it is recommended that you timely record the batch number of the products used in both cases, and conduct repeated parallel experiments, that is, use cells from the same source to spread on the supplies of these two batches for culture (pay attention to using the culture medium from the same source). Culture in the same incubator to determine the main reason why cells do not adhere to the wall.

 

* The color of the culture bottle/dish/plate I bought this time is more yellow than that of last time. Is it a product quality problem?

It is normal that plastic consumables of different batches may turn yellow after irradiation sterilization.


FAQ

Recommended Products

Return to Previous Page