01.JPG
02.JPG

Conical Centrifuge Bottles

Specification: 225 mL  250 mL  500 mL  600 mL
Bottom Type: Conical 

Get Quotation
Introduction
Product Information
Order Information
FAQ
Recommended Products

Introduction

Product Information

The conical centrifuge bottles are economical laboratory consumables for large-capacity liquid centrifugation and are suitable for large-scale cell harvesting, as well as plasmid and protein purification. These products can help researchers reduce centrifugation cycles and increase efficiency in experiments and production.
Screw seal cap ensures no leakage

Screw seal cap ensures no leakage

Designed with an engraved scale on the outer wall, clear and easy to observe

Designed with an engraved scale on the outer wall, clear and easy to observe

Features

* The bottle body is made of high-quality PP, resistant to high temperatures and high pressure, with smooth inner and outer surfaces and a uniform gloss
* Designed with an engraved scale on the outer wall, easy to observe and calibrate, with an accuracy of ±2%
* 225 mL/250 mL max centrifugal force(RCF): 7,500 xg, 500 mL/600 mL max centrifugal force RCF: 6,000 xg
* Applying screw seal cap design, 100% undergone for production line air tightness test to ensure no leakage occurs
* Recommended liquid feeding volume: 80% of max gradation volume
* Working temperature range: -80℃~121℃
* Irradiation sterilization, SAL 10-6
* DNase/RNase-free, non-pyrogenic

Material

* Tube Body: Polypropylene (PP)
* Tube Cap: High-density polyethylene (HDPE)
* Conforming to USP Class VI Standards

Product Information

Jet Biofil ENG Catalogue 2025

Catalogue

Jet Biofil ENG Catalogue 2025

Download File

Order Information


Cat. No. Capacity(mL) Maximum RCF (×g) Size Bottom Sterile Qty. Per Bag Qty. Per Case
CFT012225 225 7,500 φ: 61 mm, H:137 mm Conical Y 6 48
CFT012250 250 7,500 φ: 61 mm, H:161 mm Conical Y 6 48
CFT013500 500 6,000 φ: 95 mm, H:155 mm Conical Y 6 36
CFT041500 500 6,000 φ: 95 mm, H:147 mm Conical Y 6 36
CFT020600 600 6,000 φ: 98 mm, H:182 mm Conical Y 1 32

FAQ

Attention for the use of centrifuge tubes

* What is the maximum rotational speed that the centrifuge tubes of Jet Biofil can withstand?

21000xg. Due to the different center distance of the rotor shaft of different centrifuges, the centrifugal force generated at the same speed (rpm) is also different, so we usually use the relative centrifugal force (RCF) (g) to represent the tolerance degree of the centrifuge tube in the process of rotating centrifugation.

 

* Can the centrifuge tubes of Jet Biofil hold some kind of solution? How about its chemical compatibility?

It is necessary to pay attention to whether the sample is compatible with the material of the centrifuge tube as is used, especially if the sample is some chemical reagents or organic solvents, and the Chemical Compatibility Table of PP Plastic Materials can be used as reference. Samples with low or incompatible centrifugal compatibility are not recommended, and customers can also do pre-experiments to have a test.

 

* What is the possible reason for the burst of the centrifuge tubes in the process of centrifuge?

When centrifuging, it is necessary to pay attention to the chosen centrifugal force cannot exceed the maximum centrifugal force that the product itself can withstand.

Please notice that the maximum centrifugal force (RCF) that can be withstood may be decreased when the sample is centrifuged at low temperature or the sample is an organic solvent/volatile irritant.

 

* What should be pay attention to when using the centrifuge tubes to preserve the samples at a low temperature?

When the sample is preserved below 0 ℃, the applicability of the centrifuge tube is closely related to the composition of the solution and preservation conditions. The centrifuge tube cannot be placed on the foam support, nor the bottom of the tube is in contact with the thermal insulation materials. And please use a hollow support when preserving the samples at low temperature. Otherwise, as part of the centrifuge tube is protected by thermal insulation material, while the other part is not, the temperature difference of the overall tube body makes the tube prone to burst. In addition, please reserve a space of at least 10% of the total volume to avoid sample spillage or tube burst caused by volume expansion due to liquid solidification.

 

* Why the centrifuge tube smell special when its package is opened?

If you smell some odor in the product you receive, it is not because of the abnormal quality of the product. This is because some molecules will be vaporized and retained in the product/packaging in the process of high temperature injection molding/irradiation sterilization of the raw material plastic particles of centrifuge tube products.

The materials used for making the centrifuge tubes of Jet Biofil comply to the USP Class VI standards (USP Class VI Chapter<87>, "Biological reactivity Tests, in Vitro" and Chapter<88>, "Biological Reactivity Tests, in vivo”). No cytolysis or cytotoxic effects were observed through the verification. And the outgoing products in the process of quality inspection have passed various verification tests and are in line with the product release standards.


FAQ

Recommended Products

Return to Previous Page