内页720×540 拷贝.jpg
内页720×540 拷贝2.jpg
内页720×540 拷贝3.jpg
内页720×540 拷贝1.jpg

Lid Lock Micro Centrifuge Tubes

Specification: 0.5 mL  1.5 mL  2.0 mL  5.0 mL
Packaging: Bag

Get Quotation
Introduction
Product Information
Order Information
FAQ
Recommended Products

Introduction

Product Information

Made of transparent polymer, polypropylene (PP), the centrifuge tubes are designed with a lid lock to provide better sealability for sample protection, and to avoid accidental opening of the cap and evaporation of samples during long-term storage, ensuring safe operations.
Designed with a lid lock to avoid accidental opening of thecap

Designed with a lid lock to avoid accidental opening of thecap

Sharp bottom, smooth, transparent tube and a clear scale, facilitating volume reading

Sharp bottom, smooth, transparent tube and a clear scale, facilitating volume reading

Features

* Multiple volume and color specifications available,easy for recording and identification
* Conical bottom, smooth and transparent tube with a clear scale to facilitate volume reading
* The tube is designed with a frosted area to record experimental data
* Lid lock prevents accidental opening of cap and evaporation of samples during long-term storage, and ensures safe operations
* Maximum RCF of up to 25,000 ×g
* Temperature range: -80°C–121°C (does not deform after high-temperature sterilization and remains highly transparent)
* Sterilized by irradiation, SAL 10-6
* DNase/RNase-free, non-pyrogenic

Material

* Polypropylene (PP)
* Conforming to USP Class VI standards

Product Information

离心管运动会
Jet Biofil ENG Catalogue 2025

Catalogue

Jet Biofil ENG Catalogue 2025

Download File

Order Information


Micro Centrifuge Tubes with Lid Lock

Cat. No. Capacity (mL) Color Sterile Qty. Per Box Qty. Per Case
CFT010005 0.5 Natural N 1000 8000
CFT010015 1.5 Natural N 500 4000
CFT020015 1.5 Brown N 500 4000
CFT010020 2 Natural N 500 4000
CFT011005 0.5 Natural Y 1000 8000
CFT011015 1.5 Natural Y 500 4000
CFT021015 1.5 Brown Y 500 4000
CFT011020 2 Natural Y 500 4000


Black Micro Centrifuge Tubes with Lid Lock

Cat. No. Capacity (mL) Color Sterile Qty. Per Box Qty. Per Case
CFT030005 0.5 Black N 1000 8000
CFT030015 1.5 Black N 500 4000
CFT030020 2 Black N 500 4000
CFT031005 0.5 Black Y 1000 8000
CFT031015 1.5 Black Y 500 4000
CFT031020 2 Black Y 500 4000


Micro Centrifuge Tubes with Lid Lock, Non-sterile, 5 mL

Cat. No. Capacity (mL) Color Sterile Qty. Per Box Qty. Per Case
CFT122050 5 Natural N 200 4000
CFT123050 5 Blue N 200 4000
CFT124050 5 Yellow N 200 4000
CFT125050 5 Green N 200 4000
CFT126050 5 Rose Red N 200 4000
CFT127050 5 Black N 200 4000
CFT110050 5 Yellow N 250 2500
CFT112050 5 Black N 250 2500


Micro Centrifuge Tubes with Lid Lock, Sterile, 5 mL

Cat. No. Capacity (mL) Color Sterile Qty. Per Box Qty. Per Case
CFT322050 5 Natural Y 200 4000
CFT323050 5 Blue Y 200 4000
CFT324050 5 Yellow Y 250 2500
CFT224050 5 Yellow Y 200 4000
CFT325050 5 Green Y 200 4000
CFT326050 5 Rose Red Y 200 4000
CFT327050 5 Black Y 200 4000
CFT210050 5 Yellow Y 250 2500
CFT212050 5 Black Y 250 2500

FAQ

Attention for the use of centrifuge tubes

* What is the maximum rotational speed that the centrifuge tubes of Jet Biofil can withstand?

21000xg. Due to the different center distance of the rotor shaft of different centrifuges, the centrifugal force generated at the same speed (rpm) is also different, so we usually use the relative centrifugal force (RCF) (g) to represent the tolerance degree of the centrifuge tube in the process of rotating centrifugation.

 

* Can the centrifuge tubes of Jet Biofil hold some kind of solution? How about its chemical compatibility?

It is necessary to pay attention to whether the sample is compatible with the material of the centrifuge tube as is used, especially if the sample is some chemical reagents or organic solvents, and the Chemical Compatibility Table of PP Plastic Materials can be used as reference. Samples with low or incompatible centrifugal compatibility are not recommended, and customers can also do pre-experiments to have a test.

 

* What is the possible reason for the burst of the centrifuge tubes in the process of centrifuge?

When centrifuging, it is necessary to pay attention to the chosen centrifugal force cannot exceed the maximum centrifugal force that the product itself can withstand.

Please notice that the maximum centrifugal force (RCF) that can be withstood may be decreased when the sample is centrifuged at low temperature or the sample is an organic solvent/volatile irritant.

 

* What should be pay attention to when using the centrifuge tubes to preserve the samples at a low temperature?

When the sample is preserved below 0 ℃, the applicability of the centrifuge tube is closely related to the composition of the solution and preservation conditions. The centrifuge tube cannot be placed on the foam support, nor the bottom of the tube is in contact with the thermal insulation materials. And please use a hollow support when preserving the samples at low temperature. Otherwise, as part of the centrifuge tube is protected by thermal insulation material, while the other part is not, the temperature difference of the overall tube body makes the tube prone to burst. In addition, please reserve a space of at least 10% of the total volume to avoid sample spillage or tube burst caused by volume expansion due to liquid solidification.

 

* Why the centrifuge tube smell special when its package is opened?

If you smell some odor in the product you receive, it is not because of the abnormal quality of the product. This is because some molecules will be vaporized and retained in the product/packaging in the process of high temperature injection molding/irradiation sterilization of the raw material plastic particles of centrifuge tube products.

The materials used for making the centrifuge tubes of Jet Biofil comply to the USP Class VI standards (USP Class VI Chapter<87>, "Biological reactivity Tests, in Vitro" and Chapter<88>, "Biological Reactivity Tests, in vivo”). No cytolysis or cytotoxic effects were observed through the verification. And the outgoing products in the process of quality inspection have passed various verification tests and are in line with the product release standards.


FAQ

Recommended Products

Return to Previous Page